Showing results: 91 - 105 of 134 items found.
-
SG7501 -
Shanghai Jiuzhi Electric Co., Ltd.
SG7501 Oil Dissipation Factor and Resistivity Meter is used to measure dissipation factor, dielectric constant and resistivity for oil. The set is all-in-one structure, with internal oil cup, temperature control, AC bridge, high resistance meter, AC/DC test voltage and standard capacitor etc.
-
HDXZ-270kVA/270kV -
HD Power Test Equipment Co.ltd
HDXZ-270kVA/270kV Variable Frequency AC Resonant Test System is applied for AC dielectric test for electric equipment.1. 10kV/300mm2 cable 3km AC withstand test,capacitance≤1.1265uF,test frequency:30-300Hz, test voltage 22kV, test time 5min;2. 35kV/300mm2 cable 1km AC withstand test,capacitance≤0.1945uF,test frequency:30-300Hz, test voltage 52kV, test time 60min;3. 110kV/630mm2 cable 0.2km AC withstand test,capacitance≤0.0368uF,test frequency:30-300Hz, test voltage 128kV, test time 60min;4. 110kV/63000kVA Transformer AC withstand test,capacitance≤0.02uF,test frequency:30-300Hz, test voltage below 160kV, test time 1min;5. GIS 110kV, Switching busbar and other substation equipment, AC withstand test,test frequency:30-300Hz, test voltage below 265kV, test time 5min
-
HDXZ-162kVA/54kV -
HD Power Test Equipment Co.ltd
HDXZ-162kVA/54kV Variable Frequency AC Resonant Test System is applied for AC dielectric withstand test for electric equipment.The system is mainly composed of following parts:variable frequency control power supply,exciting transformer,reactor and capacitive divider.1. 10kV/300mm2 cable 3km AC withstand voltage test, capacitance ≤1.1265uF, test frequency 30-300Hz, test voltage 22kV, test time 5min.2. 35kV/300mm2 cable 1.5km AC withstand voltage test, capacitance ≤0.2917uF, test frequency 30-300Hz, test voltage 52kV, test time 60min.
-
Educated Design & Development, Inc.
As a general purpose dual-voltage isolation transformer for step-up (120 to 240 VAC), step-down (240 to 120 VAC), or straight 1:1 isolation (120 to 120 VAC or 240 to 240 VAC). Models with a suffix "UC" are provided with a safety jack for access to the transformer secondary center tap (connected to the transformer center tap only in the 240 VAC output setting). This connection may be used in conjunction with a Dielectric Voltage Withstand test.
-
2672AM -
Shenzhen Chuangxin Instruments Co., Ltd.
Withstand Voltage Tester is used to measure the dielectric (withstand voltage) strength, which can be intuitive, accurate and fast tested the electrical safety performance indicators of the object, such as the breakdown voltage, leakage current etc. And Withstand Voltage Tester can be used as a high voltage source to test performance of the components and whole machine.
-
TriSOL SLPSS -
OAI
The OAI Test System for HIGH EFFICIENCY SOLAR CELLS overcomes the limitations of flash testing by providing a highly optimized pulse width and voltage sweep rate to match the cell’s dielectric response speed. As a result, the system produces extremely accurate measurements of solar cell efficiency leading to increased profitability.
-
R.R.Transformers & Equipments
RR – AC DC HIPOT TESTERS can perform such precise dielectric test in a cost effective manner without any compromise on safety. Our hipot testers are custom made to suit needs of various industries and product ranges. A Singe tester can be used for conducting both AC and DC Insulation Testing.
-
Extech 380396 -
Extech Instruments Corporation
With the 380396 measure Insulation Resistance to 60GΩ with test voltages of 500V, 1000V, 2500V, and 5000V. Featuring polarization Index measurement (PI), Dielectric Absorption Ratio measurement (DAR), AC/DC Voltage measurement to 600V with Min/Max, Peak and Relative functions, and 1 to 15 minute timer function for IR measurements. Comes with test leads, eight C batteries, 220V AC adaptor, heavy duty carrying case, and user manual.
-
Extech 380395 -
Extech Instruments Corporation
With the 380395 measure Insulation Resistance to 60GΩ with test voltages of 500V, 1000V, 2500V, and 5000V. Featuring polarization Index measurement (PI), Dielectric Absorption Ratio measurement (DAR), AC/DC Voltage measurement to 600V with Min/Max, Peak and Relative functions, and 1 to 15 minute timer function for IR measurements. Comes with test leads, eight C batteries, 120V AC adaptor, heavy duty carrying case, and user manual.
-
RK7112 -
Shenzhen Chuangxin Instruments Co., Ltd.
The tester is applied to the home appliances, computer peripheral equipment, electric products, communication products, lighting products, small home appliance products, lighting equipment, electronic components, transformers, motors, compressors, electric heat pipe, wire, cable and high voltage safety system’s withstand voltage and leakage current test, as well as it’s an indispensable dielectric
-
1693 -
IET Labs
The GenRad 1693 LCR Meter Bridge gives you the best combination of features, in an LCR meter, to meet your most demanding testing requirements. It's a versatile, flexible instrument with a full range of programmable test frequencies, speeds, and voltages. An easy to understand display show both primary and secondary measurement parameters. The Digibridge is an excellent choice for metrology applications requiring accurate and repeatable measurements. The 1693 is also widely used in production testing, incoming inspection, component design and evaluation, process monitoring or dielectric measurement applications.
-
Analog Devices Inc.
The Analog Devices portfolio of dielectric resonant oscillators (DROs) and voltage controlled oscillators (VCOs) offer excellent output power and phase noise performance over temperature and cover a range of applications and uses to meet the needs of industrial, medical, aerospace and defense, EW, ECM, and communications markets. Our DRO modules are a natural choice for applications in fixed tuned or narrowband tunable configuration, while our selection of VCOs play a key role in providing reliable frequency generation for RF and microwave communication and test systems.
-
400-02 -
Srico, Inc.
Srico’s optical voltage probe uses advanced, proprietary optical chip technology to achieve precise, interference-free measurement. Our sensor and optical fibers are made of dielectric materials. This facilitates a high degree of isolation between the voltage test point and the instrumentation system ⎯ at a safe distance of 100 meters and more. This system senses, measures, and transmits electrical data very accurately.
-
Electromechanica, Inc.
The rail inverter test system uses a pulse test methodology to verify proper operation of the IGBT switching elements in a subway car motor control. The system is designed to verify proper commutation of the switching elements. A large capacitor bank allows testing at DC voltages up to 1kV and peak currents of up to 3kA into reactive loads.The system also integrates self test capabilities and safe-to-turn-on (STTO) diagnostics to ensure no gross faults are present prior to the application of high voltages. Further the system includes dielectric withstand (hi-pot) test capability to ensure electrical safety.
-
6213A IN (Ranges: 0.5kV to 10kV 0.5kV increment steps) -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bar-graph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present (>500Vac or Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.● Calculates Dielectric Absorption Ratio (DAR) automatically.● Calculates Polarization Index (PI) automatically.